• 12.1 inch color Low Power Consumption Full Touch LED Screen
• Combination of High Technology & Elegant Design
• Flexibility and Freedom to Re-configure Major Monitoring Parameters
• High-end Parameter Modules Available: IOC/AG/CO etc
• Exceptional Connectivity by High-speed Wire or Wireless Networking
• NO FAN Ultra Quiet Design Suitable for Critical Requirement
Safety IEC60601-approved Dimension and Weight Dimension: 315(W)x272(H)x 121(D)mm Weight: 4.3kg
Operation Environment Power Requirement: AC100-240V, 50/60Hz,140VA,1.4A-0.59A Temperature: 0℃-40℃ Humidity: 15%-80% (non-condensing) Patient range: Neonate, pediatric and adult patient Display: 12.1" Color TFT LCD with LED background 800*600 Resolution Multi displays selectable, including Standard display Trend coexist display Large-font display OxyCRG dynamic view display Night mode Trace: 7 traces Sweep speed: 12.5mm/s,25mm/s,50mm/s Indicator: Alarm indicator light Power indicator light Battery indicator light QRS beep and alarm sound
Li-ion Battery Rechargeable One battery about 4 hours for continuous working Two batteries option
Alarm and Indicator User-adjustable High, Medium, and Low limits 3-level audible and visual alarm Alarm indicator light Power indicator light Battery indicator light QRS beep and alarm sound Pulse rate modulation sound
Networking Wire or wireless connected to central station system
Recorder Thermal printer Real time recording Paper width: 50mm Waveform: 2 Channel (standard) Print speed: 25mm/s
ECG Input: 3-Lead or 5-Lead selectable 3 Lead cable: RA, LA, LL or R, L, F 5 Lead cable: RA, LA, RL, LL, V or R, L, N, F, C Lead selection: 3-lead: 1,11,111 5 Lead: I, II, Ill, AVR, AVL, AVF, V ECG Waveform: 2 Channel Gain selection: x0.25, x0.5, x1, x2, x4 Sweep speed: Auto 12.5mm/s, 25mm/s, 50mm/s Heart Rate: for Neonate 15-350BPM Heart Rate: for Adult/Pediatric 15-300BPM Accuracy: l bpm or 1%, whichever is greater Resolution: 1 bpm Filter Diagnostic mode: 0.05-100Hz Monitor mode: 0.5-40Hz Surgical mode: 1.0-25Hz Protection: Withstand 4000VAC/50Hz Voltage in isolation Against electrosurgical interference and defibrillation Alarm range: Neonate: 15-350BPM Adult/Pediatric: 15-300BPM ST segment detection: Measurement range: -2.0mv to 2.0mv Alarm range: -2.0mv to 2.0mv Arrythmia analysis: Yes Alarm: Audible and visual alarm, alarm event recallable Pace detection: Yes Drug dose calculation: Yes Standby mode: Yes
Respiration Method: Thoracic impedance Measurement range: Neonate/Pediatric: 0-150RPM Adult: 0-120RPM Apnea alarm: No alarm,10s,15s20s, 25s,30s,35s, 40s selectable Alarm: Audible and visual alarm, alarm events recallable | NIBP Method: Oscillometric Measurement modes: Manual/Automatic/Continuous Displayed parameters: Systolic diastolic and MAP (mean arterial pressure) Auto measure time: Adjustable Measurement unit: mmHg/kPa selectable Measurement type: Systolic, Diastolic, Mean Range of Systolic Pressure: Adult: 40-270mmHg Pediatric: 40-200mmHg Neonate: 40-135mmHg
Range of Diastolic pressure: Adult: 10-210mmHg Pediatric: 10-150mmHg Neonate: 10-100mmHg Range of Mean pressure: Adult: 20-230mmHg Pediatric: 20-165mmH Neonate: 20-110mmHg Accuracy: ±6mmHg Resolution: 1mmHg Alarm: Systolic, Diastolic, Mean Over-pressure protection: Double safety protection
IBP Channel 1 or 2 selectable Measurement range: -50-400mmHg Resolution: 1mmHg Alarm Systolic, Diastolic, Mean
SpO2 Measurement range: 0%-100% Resolution: 1% Accuracy: ±2%(70%-100%); unspecified (0-69%) Alarm range: 0-100% Pulse Rate Range: 20-254bpm Resolution: 1bpm Accuracy: ±3bpm Alarm range: 0-254bpm
Temperature Measurement range: 0-50℃ Resolution: 0.1℃ Accuracy: ±0.1℃ Channel: T1, T2, TD
EtCO2 Measurement range: 0-99mmHg Accuracy: 0 to 40mmHg ± 2mmHg 41 to 76mmHg ± 5mmHg 77 to 99mmHg ±10mmHg Sample flow rate Minimum: 50ml/m-7.5ml/m Maximum: 50ml/m+15ml/m Start-up time: <1 min, once the module starts up, it reaches ISO After 1 min, enter the full accuracy mode Respiration rate: 0 to 120rpm Respiration rate accuracy: ±2 rpm Response time: <240msec (10% to 90%)
Multi-gas/AG Method: Infrared Absorption Gas accuracy: CO2: 0 to 15vol%,±(0.2vol%+2% of reading) 15 to 25vol%, Unspecified N2O: 0-100vol%,±(2vol%+2% of reading) ENF, lSO, HAL: 0-8vol%,±(0.15vol%+5% of reading) 8 to 25vol%, Unspecified Data output: Fi and Et values Respiration Rate: 0 to 150±1RPM Other: Agent mixture detection and MAC value displayed
Interfacing 1 AC power connector 1 RJ45 network connector 2 USB 2.0 connector 1 VGA output connector 1 Multifunction output connector 1 Nurse call 1 ECG Analog output
Data Storage Trend date: 168 hours Alarm events: 100 events NIBP: 1600 recall Waveforms: Max. 4 hours Trend table/Trend graph: 1000 hours |