Technical Specifications of AcuitSign M5
Size and Weight
- Size:350mm×340mm×207mm
- Weight:≦6.5kg
- Standard module slot:4
- Additional module rack Slot:1
Power supply
- Power Voltage: AC 100-240V 50/60Hz
- Power Input: ≦150VA
- Input Current:1.7~0.8V
- Safety class: Category I
Display
- 12.1〞 Color TFT-LCD
- Resolution:800×600 pixels
Battery (Option)
- Type: Rechargeable Lithium battery,11.1V/4.0AH
- Operating time under the normal use and full charge:≧150minutes
- (2 batteries for 300 minutes)
Recorder (Option)
- Method: Thermal dot array
- Paper width:50mm(1.97 in)
- Paper length:15m
- Paper Speed:12.5/25/50(mm/sec)
- Traces: Maximum 3 tracks
- Recording way: Real-time recording, Periodic recording, Alarm recording
Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Patient Physiological Alarm Light color: Yellow & Red:
- Equipment Technical Alarm Light color: Blue
- Supports Pitch Tone and multi-level volume;
- Supports custom arrhythmia tone
Input device
- Touch screen (Option).
- knob: standard config
- Mouse input: Support
- Keyboard input: Support
System Output & Extensible Interfaces
- Ethernet Network:1 Standard RJ45 socket
- Defibrillation Output:1 RJ11 socket
- Nurse Call:1 BNC socket
- Video Output:1VGA port
- USB1.1 port:4
- Auxiliary Module Rack connector.1
- SD memory card:2G (option)
- Analog Output(ECG or IBP):Option
Trend & Reviewing
- Trend:168 hours
- NIBP measurement reviewing:1000 groups
- ARR event:128 groups of ARR event and the associated waveform
- Alarm events:128 groups of parameter alarm events and associated parameter
- Waveform at the alarm moment
Holographic waveform: The storage time depends on the stored waveforms and
the quantity of them.
Environment
- Operating temperature:0~+40℃
- Storage temperature:-20℃ to +50℃
- Operating humisity:15%to85%(non condensing)
- Storage humidity :10% to 93%(non condensing)
- Operating atmospheric pressure:860hPa to 1060hPa
- Storage atmospheric pressure:500hPa to 1060hPa
Safety:
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
ECG
- Lead Mode:3-leads ECG input
5-leads ECG input
12-leads ECG input
Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V-
Ⅰ,Ⅱ,Ⅲ, aVR,aVL,aVF,V1~V6(option)
- Gain: 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1),
20mm/mV(×2), 40mm/mV(×4),Auto
Surgery mode≦105dB
Diagnostic mode≧90dB
- Frequency response(-3d B):
Monitor mode 0.5~40Hz
Surgery mode 1~25Hz
Diagnostic mode 0.05~150Hz
- input impedance: ≧5.0Mohm
- ECG signal range:±10.0mV
- Electrode offset potential: ±500mV
- Patient Leakage Current:<10uA
- Standardizing signal:1mV±5%
- Baseline recovery:<5s after Defibrillation.(Mon or Surg mode)
- Indication of electrode separation: Every electrode(exclusive of RL)
- Protection: Breakdown Voltage 4000AVC 50/60Hz;defibrillator proof
- Sweep speed:12.5mm/s,25mm/s,50mm/s
HR
Pediatric & Neonate:10~350bpm
- Refreshing time:≦50 bpm per 2 pulses
50~120bpm per 4 pulses
≧120bpm per 6 pulses
- Resolution: 1bpm
- Accuracy:±1% or ±1bpm,whichever is greater
ST segment
- Measurement range:-2.0mV~2.0mV
- Accuracy:-0.8mV~0.8mV: ±0.02mV or ±10% whichever is greater
Over ±0.8mV:unspecified
RESP
- Method: Thoracic impedance
- Lead Selected from:Ⅰ(RA-LA)orⅡ(RA-LL);Default:Ⅰ
- Gain:×0.25, ×1, ×2, ×4
- Bandwidth:0.25Hz to 2.0Hz (-3dB)
- Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s
- Measurement Range:0~150 rpm
- Resolution: 1rpm
- Accuracy: ±2rpm or 2% whichever is greater
- Delay of Apnea Alarm:10s,15s,25s,30s,35s,40s,45s,50s,55s,60s
NIBP
- Way of measurement: Automatic oscillometry
- Range of measurement:
Adult: SYS 30~270mmHg
DIA 10~220mmHg
MAP 20~235mmHg
Child: SYS 30~235mmHg
DIA 10~220mmHg
MAP 20~225mmHg
Neonate: SYS 30~135mmHg
DIA 10~100mmHg
MAP 20~125mmHg
- Cuff pressure range:0~300mmHg
- Resolution:1mmHg
- Pressure Accuracy: Static:±2% or ±3mmHg,whichecer is greater
Clinical: ±5mmHg average error
Standard deviation:≦8mmHg
- Unit: mmHg, kPa
- Measurement mode: Manual, Auto, STAT
- Intervals for AUTO measurement time:1,2,3,4,5,10,15,30,60,90 minutes;
2,4,8,12hours
- STAT mode cycle time: keep 5 minutes, at 5 seconds interval.
- Overpressure Protection: Hardware and software double protections
- Pulse rate range:40~240bpm
Standard SpO2(Digital)
- Measurement Range:0~100%
- Resolution:1%
- Accuracy: At70~100%,±2%
At0~69%,unspecified
PR
- Measurement Range:25~255bpm
- Resolution:1bpm
- Accuracy: ±1% or ±1bpm,whichever is greater
Nellcor-SpO2
- Measurement Range:0~100%
- Resolution:1%
- Accuracy:At70~100%:±2%(Adult)
At70~100%:±3%(Neonate)
At70~100%:±2%(Low Perfusion)
At0~69%,unspecified
PR
- Measurement Range:20~300bpm
- Resolution:1bpm
- Accuracy: 20bpm to 250bpm: ±3bpm
251bpm to 300bpm: unspecified
Masimo-SpO2
- Measurement Range:0% to 100%
- Resolution:1%
- Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion conditions)
70% to 100%:±3%(neonate,non-motion conditions)
70% to 100%:±3%(motion conditions)
0% to 69%, unspecified
- Average time:2-4s,4-6s,8s,10s,12s,14s,16s
PR
- Measurement Range:25bpm to 24bpm
- Accuracy: ±3bpm(non-motion conditions)
±5bpm(motion conditions)
TEMP
- Max Channel: 8
- Measurement way: Thermal resistance way
- Measurement Range: 0.0℃~50.0℃(32℉~122℉)
- Accuracy: ±0.1℃ or ±1℉(exclusive of probe)
- Resolution: 0.1℃ or 1℉
- Unit: Celsius(℃),Fahrenheit(℉)
- Connecting cable: Compatible with YSI-400 serial
IBP
- Max Channel: 8
- Measurement way: Directly invasive pressure measurement
- Sensitivity of transducer: 5uV/V/mmHg, ±2%
- Impedance of transducer: 300 to 3000Ω
- Measurement Range: -50~+350mmHg
- Resolution: 1mmHg
- Unit: mmHg, kpa, cmH2O
- Accuracy:
Static: ±1mmHg or ±2%, whichever is grater(exclusive of transducer)
±4mmHg or ±4%, whichever is grater(inclusion of transducer)
Dynamic: ±4mmHg or 4%, whichever is grater
Transducer sites: Arterial Pressure (ART)
Pulmonary Artery Pressure (PA)
Left Atrium Pressure (LAP)
Right Atrium Pressure (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/P2
- Selection of measurement range:
ART:0~+350mmHg
PA:-10~+120mmHg
CVP/RAP/LAP/ICP:-10~+40mmHg
P1/P2:-50~+350mmHg
EtCO2(Sidestream)
- Measure method: Infrared spectrum
- Measure Range: 0.0~13.1%(0~99.6mmHg)
- Resolution: 1mmHg
- Unit: %,mmHg,kpa
- Accuracy: 0% to 4.9%,±0.3%(±2.0mmHg)
5.0%to 13.1%,<±10%of the reading
- Measurement range of awRR:3~150rpm
- Calibration: Offset calibration:auto,manual,Gain calibration
EtCO2(Mainstream)
- Measure method: Infrared spectrum
- Warm up time: Capnogram displayed in less than 15 seconds,At an ambient
Temperature of 25℃, full specifications within 2 minutes.
- Measure Range: 0.0~19.7%(0~150mmHg)
- Resolution: 1mmHg
- Rise time(10l/min):≦60ms
- Unit: %,mmHg,kpa
- CO2 Accuracy:0-40mmHg, ±2mmHg
41-70mmHg, ±5% of reading
71-100mmHg, ±8% of reading
101-150mmHg, ±10% of reading
(at 760 mmHg,ambient temperature of 35℃)
- awRR measurement range:0~150rpm
- awRR measurement Accuracy: ±1rpm
EtCO2(Microstream)
- Measure method: Infrared spectrum
- Warm up time: Capnogram displayed in less than 20 seconds, At an ambient
Temperature of 25℃,full specifications within 2 minutes.
- Measure Range: 0.0-19.7%(0-150mmHg)
- Resolution: 1mmHg
- Unit: %,mmHg,kpa
- CO2 Accuracy: 0-40mmHg, ±2mmHg
41-70mmHg, ±5% of reading
71-100mmHg, ±8% of reading
101-150mmHg, ±10% of reading
(At 760 mmHg,ambient temperature of 25℃)
(When RR>80 rpm, all the rang is ±12% of reading)
CO2 response time: <3S
- awRR measurement range:2~150rpm
- awRR measurement Accuracy: ±1rpm
- Sample Flow Rate:50ml/min ±10ml/min
Multi Gas
- Measure method: Infrared spectrum
- Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,NEF,SEV,DES)
- Resolution:1%
- Unit:%
- Calibration: Room air calibration automatically when changing airway
Adapter (<5 sec)
- Warm-up time:<10S,full accuracy within 1min
- Measurement and alarm range of AG
- Gas Range Accuracy
CO2 0-10% ±(0.3% ABS+4%REL)
N2O 0-100% ±(2% ABS+8%REL)
O2 10-100% ±(2% ABS+2%REL)
HAL,ISO,ENF 0-5% ±(0.15% ABS+10%REL)
SEV 0-8% ±(0.15% ABS+10%REL)
DES 0-18% ±(0.15% ABS+10%REL)
- awRR measurement range: 0~150rpm
- awRR measurement Accuracy: ±1rpm
- Rise time(flowing speed 10I/min)CO2≦90ms
O2≦300ms
N2O≦300ms
Hal,Iso,Enf,Sev,Des≦300ms
- Total system response time :<1seconds
Noninvasive Cardio Output (ICG):
Method: Measurement of thoracic electrical bioimpedanc
- Measurement Range:HR:40~250bpm
SV:5~250ml
SI:5~125ml/m2
C.O.:1.4~15L/mm
TFC:15~143KΩ
SV: unspecified
C.O unspecified
- Alarm range: C.L.:0.0L/min/m2 to 15.0 L/min/m2 continuously adjustable
TFC: 10/KΩ to 150/kΩ continuously adjustable.
Standard Configuration:
Mainunt:12.1″ TFT-LCD display,4 Standard module slot,1Additional module rack Slot(for EMS all-in-one module), 1 RJ45 internet socket,1 Defibrillation Outpit,1 Nurse Call socket,1VGA port,4 USB1.1 port,1 Auxiliary Module Rack connector
Option of AcuitSign M5:
EMS module: 8 Kinds of option
Option Module: Sidesteam CO2 module, Microstream CO2 module, Mainstream CO2 module, AG module, ICG module, IBP module, Temp module, , Nellcor SpO2 module, Masimo SpO2 module, SD Memory
Module Rack: Auxiliary Module Rack
Navigating: USB compatible mouse and keyboard.
Printing: 3 Channel Thermal Recorder
Mounting: Rolling stand, Wall mount
Battery: 11.1V/4.0AH Rechargeable Lithium Battery (max 2 pcs),
Other options: External Display, Wireless Lan, Extensive Memory card, Analog Output (ECG or IBP), Full Touch Screen